Plantronics R-410A Instrukcja Użytkownika

Przeglądaj online lub pobierz Instrukcja Użytkownika dla Klimatyzatory typu split Plantronics R-410A. Plantronics R-410A User's Manual Instrukcja obsługi

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj

Podsumowanie treści

Strona 1 - This system uses

R-410AThis system usesM00036-V00

Strona 2

Installation & service manual _7WIRING SYSTEM DIAGRAMS3 2 1Terminal block of indoor unit3 2 1L1 L2Terminal block of outdoor unitPower supply, 1 ph

Strona 3 - CONTENTS

1. The indoor unit is powered from the outdoor unit. A sufficient length of conduit and wiring shall be used from the outdoor unit to the indoor unit.

Strona 4 - SAFETY CONSIDERATIONS

When connecting the refrigerant tubing- Keep all tubing runs as short as possible.- Use the flare method for connecting tubing.- Apply refrigerant lub

Strona 5 - ACCESSORIES

Installation & service manual _10REFRIGERANT R410A: SPECIAL PRECAUTIONS WHEN INSTALLING UNITGeneral InformationSystems using R-410A refrigerant ru

Strona 6 - INCORRECT

Installation & service manual _11TIGHTENING REFRIGERANT PIPING CONNECTIONSCaution:Remove the protection caps on the pipes and connect the assembly

Strona 7 - Air inlet

Installation & service manual _12SYSTEM EVACUATIONCondensing unit liquid and suction valves are closed to contain the charge within the unit. The

Strona 8 - ELECTRICAL INSTALLATION

Installation & service manual _13ADDITIONAL CHARGE AND DISTANCERefrigerant suitable for a piping length of 20 ft (6 m) is charged in the outdoor u

Strona 9 - 3 2 1L1 N

Installation & service manual _14GAS LEAK CHECKCheck that no gas escapes from the connections by using a leak detector or soapy water.A and B are

Strona 10 - 3 2 1L1 L2

Installation & service manual _15CHECKING AND TESTING OPERATIONSPerform the operation test after completing the gas leak check of the flare nut co

Strona 11 - OUTDOOR UNIT

Installation & service manual _16TECHNICAL SPECIFICATIONSSPECIFICATIONS*Note: Design and specifications are subject to change without notice for p

Strona 12 - Outdoor unit

Installation & service manualIMPORTANT! Please Read Before StartingThis air conditioning system meets strict safety and operating standards. As th

Strona 13

InABCDEFGHIModels: 9SRA-HE | 12SRA-HE | 15SRA-HE | 18SRA-HE | 24SRA-HEIndoor unitOutdoor unitAFBDEHIGCInstallation & service manual _17OUTLINE AND

Strona 14

Installation & service manual _18PARTS DIAGRAM (INDOOR UNIT)INSIDE UNIT9SRAI-HE12SRAI-HE15SRAI-HE18SRAI-HE24SRAI-HE

Strona 15 - SYSTEM EVACUATION

REF.NODESCRIPTION QTY9SRAI-HE 12SRAI-HE 15SRAI-HE 18SRAI-HE 24SRAI-HE1Faceplate (including display glass) 1P00843 P00843P00844 P00844 P008452Lamp boa

Strona 16

Installation & service manual _20PARTS DIAGRAM (OUTDOOR UNIT)OUTSIDE UNIT9SRAO-HE12SRAO-HE15SRAO-HE18SRAO-HE24SRAO-HE

Strona 17 - GAS LEAK CHECK

Installation & service manual _21PARTS LIST (OUTSIDE UNIT)REF.NODESCRIPTION QTY9SRAO-HE 12SRAO-HE 15SRAO-HE 18SRAO-HE 24SRAO-HE1 Cabinet | Front L

Strona 18 - Auxiliary control button

Installation & service manualNOTE

Strona 19 - TECHNICAL SPECIFICATIONS

8201 W. Calumet Road, Milwaukee, WI 53223 USAwww.williamson-thermoflo.com

Strona 20 - OUTLINE AND DIMENSIONS

Installation & service manualCONTENTSSafety considerations 1Accessories 2Installation recommendations (indoor unit) 3Installation recommendations

Strona 21 - PARTS DIAGRAM (INDOOR UNIT)

This manual is a guide for properly installing the Williamson-Thermoflo Wall-mounted split air conditioner. Improperinstallation can result in unsafe

Strona 22 - PARTS LIST (INSIDE UNIT)

The following accessories are supplied with the air conditioner.• The quantities are indicated in parenthesi s.Installation plate (1) Remote control (

Strona 23 - PARTS DIAGRAM (OUTDOOR UNIT)

1. Before fixing the installation plate to a wall, you must determine the position of the 2 3/4 in (70 mm) hole through whichthe conduit, piping and d

Strona 24 - PARTS LIST (OUTSIDE UNIT)

Attach the outdoor unit with 4 anchor bolts and nuts (not supplied) positioned as per dimensions A, B.9SRAO-HECaution:The outdoor unit should not be e

Strona 25

1. The air conditioner shall be installed by a qualified technician in accordance with national and local electrical codes.2. A disconnect switch sha

Strona 26

3 2 1Terminal block of indoor unit3 2 1L1 NTerminal block of outdoor unitPower supply, 1 phase, 60 HzINDOOR UNIT OUTDOOR UNITInstallation & servic

Komentarze do niniejszej Instrukcji

Brak uwag